Design | |
---|---|
Colour |
Stainless steel
|
Operating modes | |
Type of air guide |
Convertible
|
User convenience | |
Power levels (number without Booster level) |
3
|
Efficiency and sustainability | |
Energieeffizienzklasse (A++ - E) |
C
|
Annual energy consumption in kWh/year |
59.1
|
Fluid dynamic efficiency class |
D
|
Lighting efficiency class |
A
|
Filter system | |
Number of dishwasher safe stainless-steel grease filters (10-ply) |
2
|
Lighting | |
Light intensity in Lx |
360
|
Colour temperature in K |
3,000
|
Air throughput with max. duct diameter in extraction mode (not for external version) | |
Air throughput in Level 1 (m³/h) according to EN 61591 |
150
|
Air throughput in Level 2 (m³/h) according to EN 61591 |
250
|
Air throughput in Level 3 (m³/h) according to EN 61591 |
350
|
Air throughput in Booster level (m³/h) according to EN 61591 |
500
|
Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3 |
41
|
Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3 |
47
|
Sound power in Level 3 (dB(A) re 1 pW) according to EN 60704-3 |
55
|
Sound power in Booster level (dB(A) re 1 pW) acc. to EN 60704-3 |
62
|
Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13 |
26
|
Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13 |
34
|
Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13 |
40
|
Sound power in Booster level (dB(A) re 20 µPa) acc. to EN 60704-2-13 |
47
|
Air throughput in recirculation mode | |
Air throughput in Level 1 (m³/h) according to EN 61591 |
100
|
Air throughput in Level 2 (m³/h) according to EN 61591 |
150
|
Air throughput in Level 3 (m³/h) according to EN 61591 |
250
|
Air throughput in Booster level (m³/h) according to EN 61591 |
350
|
Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3 |
48
|
Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3 |
55
|
Sound power in Level 3 (dB(A) re 1 pW) according to EN 60704-3 |
61
|
Sound power in Booster level (dB(A) re 1 pW) acc. to EN 60704-3 |
68
|
Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13 |
34
|
Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13 |
41
|
Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13 |
47
|
Sound power in Booster level (dB(A) re 20 µPa) acc. to EN 60704-2-13 |
53
|
Technical data | |
Overall height for extraction mode and external mode cooker hoods in mm |
695
-
1,015
|
Overall height for recirculation mode cooker hoods in mm |
825
-
1,145
|
Canopy width in mm |
598
|
Canopy height in mm |
120
|
Canopy depth in mm |
520
|
Minimum height above electric hobs in mm |
450
|
Net weight in kg |
21.0
|
Length of supply lead in m |
1.5
|
Total rated load in kW |
0.13
|
Voltage in V |
230
|
Fuse rating in A |
10
|
Number of phases |
1
|
Installation notes | |
Diameter of extraction ducting connection in mm |
150
|
Special Order